A LiV travel trailer on a gravel storage pad among pines at a cold, clear autumn dusk

Winterizing your LiV

Eight steps that protect every LiV's plumbing, plus storage, cold-weather camping and spring start-up.

Before you start

Before the freeze

Winterize before the next hard freeze. Water left in a line expands as it freezes and can split a pipe, a fitting or a water heater. In the South it only takes one cold night.

  • Last winter's low near Americus: 18°F (Plains, GA, about 10 mi away)
  • Last winter's low near Crossville: 4°F (Crossville Memorial Airport)
  • Last winter's low near Hudson: 17°F (Brooksville, about 20 mi away)

The LiV limited warranty excludes damage from “environmental conditions (e.g., … freeze damage …)”, so winterizing is how you protect the plumbing.

Allow 2–4 hours the first time.

What you need

  • RV antifreeze: propylene glycol, rated −50°F, full strength. Most LiVs take 2–4 gallons.
  • A blow-out plug and an air compressor with a regulator, if you’ll blow out the lines
  • A pump converter kit, or a hand-pump kit
  • Tire covers

The eight steps

Winterize, step by step

Winterize your LiV in 8 steps. 1, Drain the tanks: fresh first, black, then gray, at a dump station; close the valves. 2, Water heater: off and drained, the way its label says. 3, Open every drain: low points, every faucet hot and cold, the outside shower; pull the filters, empty the pump. 4, Blow out the lines: 20–30 psi through a regulator, never over 40. 5, Pump in RV antifreeze: through a pump converter, to each faucet until pink; keep it out of the water heater (step 2). 6, Drains and toilet: a cup in each P-trap; flush the toilet until pink. 7, Battery: lead-acid full and disconnected; lithium, follow its maker. 8, Outside: tires covered, seals checked, a breathable cover, a tag on the water inlet. RV antifreeze only, full strength. Never automotive.
The eight steps on one page. Save it to your phone for winterizing day.
  1. Step 1: Drain the tanks

    • Drain the fresh water tank first.
    • At a dump station, empty the black tank, then the gray tank, so the gray water rinses the hose.
    • Close all the tank valves once they’re empty.
  2. Step 2: Water heater

    • Turn off its power and gas and let it cool, then drain it the way its label says.
    • LiVs have been built with different water heaters, and their makers disagree on bypassing and antifreeze, so read yours first:

    First, read the label inside the water heater’s outside access door. It names the maker and model.

    6-gallon tank heater (it has a drain plug)

    • Turn off the power and gas, and let the water cool.
    • Open the pressure-relief valve, then remove the drain plug and let it empty.
    • If you’ll pump antifreeze, set its bypass first: bypass it before antifreeze goes in, so the tank doesn’t fill with it.
    • Leave the anode rod out unless its manual calls for one. Dometic’s aluminum tanks don’t use one.

    On-demand (tankless) heater

    • Turn off the power and gas.
    • Drain it the way its label or manual says.
    • Some makers want it bypassed before antifreeze, and others allow antifreeze through it, so follow yours.
    • Its freeze protection needs power and propane, and it protects only the heater itself, not your lines.

    Electric water heater (Go-Anywhere Electric package)

    • Switch its breaker off before you drain it.
    • Drain it the way its label or manual says.
    • In spring, refill it until water flows steadily from the hot tap before the breaker goes back on. Even brief heating while it’s empty can burn out the element.

    If you're not sure, do this

    Not sure, or no manual?

    • Send a photo of the label to Warranty & Support (opens in a new tab) and we’ll tell you which heater you have. For parts, see FDMRVParts.com (opens in a new tab).
    • Until you know, do it the way that works for every heater: turn off the power and gas, drain it, and keep antifreeze out of it.
    • If your LiV has bypass valves, set them to bypass.
    • If it doesn’t, blow out the lines at 20–30 psi and put antifreeze only in the drains and the toilet.
  3. Step 3: Open every drain

    • Open the low-point drains (your owner’s manual shows where they are) so the lines can empty.
    • Open every faucet, hot and cold, and the outside shower.
    • Pull the water filter cartridges and empty the housings.
    • Run the water pump for a few seconds to push out the water inside it, then turn it off and close everything back up.
  4. Step 4: Blow out the lines

    • Blowing out the lines is optional, but we recommend it: less water is left behind to thin the antifreeze.
    • Fit a blow-out plug to the city-water inlet and set the compressor’s regulator to 20–30 psi. Never go over 40 psi.
    • Open one faucet at a time, hot and cold, until only air comes out. Do the outside shower and flush the toilet too.
  5. Step 5: Pump in RV antifreeze

    • First, check step 2: if your water heater has to stay free of antifreeze and your LiV has no bypass valves, skip this step. Blow out the lines and go on to step 6.
    • Use RV antifreeze only, full strength: never dilute it, and never use automotive antifreeze.
    • Fit a pump converter kit to the water pump’s inlet and put its tube in the jug, so the pump draws antifreeze and protects itself.
    • Turn the pump on and open each faucet, hot and cold, until pink comes out. Then the outside shower, and flush the toilet until pink.
    • Last, press the city-inlet check valve until pink shows.
    • No pump converter? A hand-pump kit pushes antifreeze in through the city-water inlet, but it can’t reach the water pump, so drain the pump separately.
  6. Step 6: Drains and toilet

    • Pour about a cup of RV antifreeze into each sink and shower drain, so the P-traps hold pink instead of water.
    • Flush the toilet until pink shows in the bowl.
    • Add a little to each holding tank through a drain and the toilet, to protect the valves and seals.
  7. Step 7: Battery

    • Lead-acid: charge it full, then disconnect it or keep it on a maintainer. A full battery resists freezing; a low one doesn’t.
    • Lithium: follow its maker’s storage steps and disconnect every load.
  8. Step 8: Outside

    • Set the tires to placard pressure and cover them.
    • Walk around and check the roof, window and door seals.
    • Use a breathable RV cover, never a plastic tarp.
    • Hang a tag on the city-water inlet so nobody hooks up water before spring.

While it waits

Store it

A stored LiV faces more than cold: a flat battery, sun on the tires and mice do as much harm. Go through these when you put it away.

  • Battery

    Lead-acid: store it full and disconnected, because a battery at 40% charge freezes near 5°F. Lithium: follow its maker and disconnect every load. The LP/CO alarm keeps drawing power and can flatten a battery in about three weeks, so check what your disconnect switch cuts.

  • Tires

    Keep them at placard pressure, cover them with opaque covers against the sun, block them, and move the trailer a little every few months.

  • Cover

    A breathable RV cover or a carport, never a plastic tarp, which traps moisture.

  • Mice

    Seal any gap of ¼ inch or more with metal (mice chew through foam), and set snap traps. Ultrasonic devices, dryer sheets and mothballs don’t work.

  • Fridge

    Turn it off, empty it, and prop the door open.

  • Propane

    Close the propane cylinder valves.

  • Seals

    Walk around the roof, windows and doors and look for gaps. The warranty excludes “failure to properly maintain or service the Vehicle, including but not limited to the maintenance of lubricants, sealants, and seals”.

  • Moisture

    A closed-up trailer collects condensation. Our moisture guide shows how to keep it dry.

  • Visits

    Check on it once a month, or use a remote temperature and humidity monitor.

  • Truck campers: follow your camper’s manual for resting it off the truck.

Using it in winter

Camping in the cold

Camping on a night near freezing takes a plan for water, tanks, heat and power. Run this checklist before you go.

Freeze-night checklist

Water

  • A heated hose rated below the night’s low helps keep fresh water flowing; wrap and insulate the spigot and connections too.
  • Or fill the fresh tank, run on the pump, and disconnect and drain the hose.

Tanks

  • Keep the tank valves closed until you dump.
  • Tank heater pads help keep holding tanks from freezing while they have 12-volt power; they protect the tanks, not your water lines or valves.

Heat

  • Use the furnace, if your LiV has the optional LP furnace, and keep the propane cylinders above half full.
  • Never the range or oven for heat, and no unvented propane heaters inside.
  • If you use a space heater, use a 1,500 W heater with tip-over and overheat shutoff, and follow the rules below.
  • A space heater near the thermostat can keep the furnace from coming on.

Power

  • A 30-amp site gives you about 3,600 W. A 1,500 W heater uses almost half of it, so run one big load at a time.
  • Lithium batteries shouldn’t be charged below freezing. Many have built-in protection that blocks it, but check your battery’s manual before you charge in the cold. They also hold less: about 80% of their rating at 32°F.

Air

  • Test the CO/LP and smoke alarms before each trip.
  • Crack a roof vent: cold nights bring condensation. The moisture guide shows how to keep it dry.

Go-Anywhere Electric trades propane appliances for electric ones, so plan your heat before a cold trip. What heats your LiV depends on its model and options: on the 13, 16 and 17 series the heat-pump A/C heats in mild weather, down to about 40°F; on other models the A/C only cools. Not sure what yours has? Ask your LiV dealer or Warranty & Support (opens in a new tab), with your model.

No furnace? Drain before bed.

  • On a night forecast at or below 32°F, treat your LiV as unheated.
  • Before bed, turn off the water pump and the water heater's power and gas, then drain the water lines and the water heater, the way its label says.
  • Use jug water until morning.
  • Pour RV antifreeze in the drains.
  • In the morning, close the low-point drains and the water heater's drain, then refill the heater until water flows steadily from a hot tap. Only then turn its power or gas back on.
  • Run a space heater only while someone is awake.

Space heater rules

  • Plug it straight into a wall outlet at a 30-amp site, one heater at a time.
  • Never run a space heater on a household outlet, a 15-amp adapter, an extension cord or a power strip.
  • Keep anything that can burn 3 feet away on every side.
  • Turn it off when you sleep or leave.
  • Keep a working smoke alarm and CO alarm.

De-winterizing

Spring start-up

In this order: flush with the water heater still bypassed, then refill it before power or gas. That saves it from the most common spring mistake.

  1. Wait for warm nights

    Start once nights stay above freezing.

  2. Close everything up

    Close the low-point drains and the water heater’s pressure-relief valve, put its drain plug back (with the anode rod only if its manual calls for one), and set the pump converter back to normal.

  3. Flush with the water heater still bypassed

    Leave the bypass set (if your LiV has one), connect fresh water and run every faucet, hot and cold, the outside shower and the toilet until the water runs clear with no pink.

  4. Set the bypass back

    Return the bypass valves to normal so water can reach the heater.

  5. Refill the water heater before power or gas

    Fill it completely and bleed the air: open a hot tap and wait until water flows steadily from the hot tap with no sputtering. Only then turn on the gas or power. On an electric heater the breaker stays off until then.

  6. Sanitize

    Following NFPA 1192, mix ¼ cup of household bleach in a gallon of water for every 15 gallons of fresh tank. Pour it in, fill the tank and run it to every tap. Let it sit 4 hours, then drain and flush with fresh water until there’s no chlorine smell.

  7. New filter cartridges

    Fit new cartridges in the filter housings.

  8. Check for leaks

    With the pump on, look under the sinks, around the water heater and at the low-point drains for drips.

  9. Battery back on

    Charge it and reconnect it.

  10. Test the alarms

    Test the CO/LP and smoke alarms before the first trip.

  11. Tires

    Check them for cracks and set them to placard pressure.

Questions

Winter questions

Do I need to winterize in Georgia or Florida?

Yes, if your LiV will sit through a freeze. Last winter it hit 18°F near Americus, Georgia, and 17°F near Brooksville, Florida, and one hard freeze is enough to split a line. If you’ll keep using your LiV through the winter, follow the freeze-night checklist on cold nights, and winterize it whenever it will sit through a freeze between trips.

Is blowing out the lines enough?

It removes most of the water, but some always stays in low spots, traps and valves. We recommend blowing out the lines and then adding RV antifreeze. If your water heater has to stay free of antifreeze and you have no bypass valves, blow out the lines and put antifreeze only in the drains and the toilet.

How much RV antifreeze do I need?

Most LiVs take 2–4 gallons if you pump it to every faucet. If you blow out the lines and protect only the drains, toilet and tanks, 1–2 gallons is usually enough.

Can antifreeze go through my water heater?

It depends on the heater. If it’s a 6-gallon tank heater, bypass it so the tank doesn’t fill with antifreeze. On-demand heaters differ: some makers want them bypassed and others allow antifreeze through, so follow its label or manual. Not sure which you have? Send a photo of the label to Warranty & Support (opens in a new tab).

Does the warranty cover freeze damage?

No. The LiV limited warranty excludes damage from “environmental conditions (e.g., … freeze damage …)”. Winterizing before the next hard freeze is how you protect the plumbing.

What heats my LiV overnight?

On a LiV with a propane furnace, the furnace does. A space heater is for while you’re awake and in the trailer: turn it off when you sleep or leave. Not sure whether your LiV has a furnace? Ask your LiV dealer or Warranty & Support (opens in a new tab), with your model.

Can I run a space heater in my LiV?

Yes, while you’re awake and in the trailer. Use a 1,500 W heater with tip-over and overheat shutoff, plugged straight into a wall outlet at a 30-amp site, one heater at a time. Keep anything that can burn 3 feet away on every side, turn it off when you sleep or leave, and keep a working smoke alarm and CO alarm.

Does an electric LiV heat itself in winter?

Not on a freezing night. On the 13, 16 and 17 series the heat-pump A/C heats in mild weather, but RV heat pumps stop heating around 40°F, and on other models the A/C only cools. Below that you need another heat source: a propane furnace if your LiV has one, or a 1,500 W electric heater on 30-amp shore power.

Do I need a CO alarm in an electric LiV?

Yes. Keep a working CO alarm in every LiV, electric or not: a generator, a neighbor’s exhaust or a propane appliance can all put carbon monoxide in the air. Test it before each trip.

Can I charge a lithium battery in the cold?

Lithium batteries shouldn’t be charged below freezing. Many have built-in protection that blocks it, but check your battery’s manual before you charge in the cold. They also hold less: about 80% of their rating at 32°F.